Seite 1 - Thermostat Wiring Guide

1CT70Heat PumpThermostat Wiring Guide

Seite 2

10Typical wiring hookup of CT70 with jumper intact.M8504W2W1XOEGY1RLBL1 (HOT)L21POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQ

Seite 3 - HOW TO USE THIS GUIDE

11AMANA! Jumper these two terminals if both are present# This terminal must be connected to transformer common.$ Remove this factory-installed jumper

Seite 4

12BARD/JANITROL/TAPPAN/WILLIAMSON! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.$ Connect multiple

Seite 5 - TABLE OF CONTENTS

13ARCOAIRE/SNYDER GENERAL/COMFORTMAKER! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.Wiringterminal

Seite 6 - HEAT PUMPS ARE DIFFERENT

14B.D.P. (BRYANT-DAY/NIGHT-PAYNE)! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.$ Connect multiple

Seite 7 - SEVERE WEATHER

15CARRIER! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.WiringterminalfunctionExistingthermostatwir

Seite 8

16FRIEDRICH! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.$ Tape off the end of the wire. Jumper is

Seite 9

17HEIL QUAKER/WHIRLPOOL/TEMPSTAR! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.Wiringterminalfuncti

Seite 10

18LENNOX! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.RWiringterminalfunctionExistingthermostatwir

Seite 11

19RHEEM/RUUD! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.WiringterminalfunctionExistingthermostat

Seite 13

20TRANE/AMERICAN STANDARD! This terminal must be connected to transformer common.# Leave factory-installed jumper in place.$ Tape off end. CT70 replac

Seite 14

21YORK/BORG WARNER/LUXAIRE (MONCRIEF, FRASER-JOHNSTON)! This terminal must be connected to transformer common.# Connect multiple second stage heating

Seite 15

22YORK/BORG WARNER! This terminal must be connected to transformer common.# Remove factory-installed jumper.WiringterminalfunctionExistingthermostatwi

Seite 17

69-0866—2 C.H. Rev. 01-95 www.honeywell.com/yourhomeAutomation and Control SolutionsHoneywell International Inc.1985 Douglas Drive NorthGolden

Seite 18

3HOW TO USE THIS GUIDEBefore you disconnect the wires and remove your existing thermostat, be sure this new thermostat, see the CT70 wiring hookup dia

Seite 20 - TRANE/AMERICAN STANDARD

5TABLE OF CONTENTSHow to Use This Guide ... 3Heat Pumps are Different ...

Seite 21

6HEAT PUMPS ARE DIFFERENTHeat pump systems usually have a supplemental, Second Stage heating system that operates only when necessary. This heat pump

Seite 22 - YORK/BORG WARNER

7HEAT PUMPS ARE TWO SYSTEMS IN ONEIn mild weather, virtually all of the demand for heat in buildings can be met by the heat pump compressor. This Firs

Seite 23

8DEFINITIONS OF TERMINAL FUNCTIONSEach terminal of the CT70 controls a different heat pump function. Here is a list of the possible heat pump function

Seite 24 - Golden Valley, MN 55422

9FAN:When this terminal is activated, the fan is on. With the fan switch in the auto position, the fan cycles on and off with the heat pump. With the