INSTALLATION INSTRUCTIONS
69-2076-01
S9360A, S9361A, S9370A, S9371A
Integrated Boiler Controllers
APPLICATION
These integrated boiler control modules provide ignition
sequence, flame monitoring and safety shutoff for either
intermittent pilot spark ignition or direct hot surface
ignition heating systems. They also provide limit rated
water temperature control and display interface capability
for either “on-board” or remote user interface
applications.
S9360A—Spark Ignition, Intermittent Pilot, Remote
Display.
S9361A—Spark Ignition, Intermittent Pilot, “On board”
Display.
S9370A—Hot Surface Ignition, Remote Display.
S9371A—Hot Surface Ignition, “On board” Display.
Enabled with EnviraCOM™ communication capability
to support remote monitoring and diagnostics.
Limit-rated Temperature Sensing Probe.
One or Two Sensor Models.
SPECIFICATIONS
IMPORTANT:
The specifications given in this publication do
not include normal manufacturing tolerances.
Therefore, an individual unit may not match the
listed specifications exactly. Also, this product is
tested and calibrated under closely controlled
conditions, and some minor differences in
performance can be expected if those
conditions are changed.
Model Numbers
Dimensions:
See Fig. 1.
S—Switching Control
93—Integrated Hydronic Control Platform
6—Spark Ignition
7—Hot Surface Ignition
0—Remote Display Required
1—Integrated On-Board Display
A—Boiler Control
B—Water Heater Control
C—Pool Heater Control
1—No Circulator
2—On/Off Circulator
S9360A1000
Seitenansicht 0
1 2 3 4 5 6 ... 15 16

Inhaltsverzeichnis

Seite 1 - Integrated Boiler Controllers

INSTALLATION INSTRUCTIONS69-2076-01S9360A, S9361A, S9370A, S9371AIntegrated Boiler ControllersAPPLICATIONThese integrated boiler control modules provi

Seite 2 - 69-2076—01 2

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS69-2076—01 10Table 5. Spark Model Specific Connectors.a Indicates optional connections bas

Seite 3 - INSTALLATION AND CHECKOUT

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS11 69-2076—01“SP_” Setpoint.“Df_” Setpoint Differential (select models).“°F_” Degrees Fahr

Seite 4 - Mount Module

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS69-2076—01 12Mounting Sensor and ThermowellThe remote upper temperature sensor is installe

Seite 5 - Wire the System

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS13 69-2076—01Fig. 10. Operating Sequence.IGNITIONSEQUENCE IDLEALL OUTPUTS OFFCHECK LEAKAGE

Seite 6 - Ground Control System

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS69-2076—01 14TROUBLESHOOTINGIMPORTANT1. The following service procedures are provided as a

Seite 7 - 7 69-2076—01

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS15 69-2076—01Table 7. Error Codes.Segment Display Definition Pressure Switch failed to ope

Seite 8 - Common Connectors

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERSAutomation and Control SolutionsHoneywell International Inc. Honeywell Limited-Honeywell L

Seite 9 - HSI Model Specific Connectors

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS69-2076—01 2Fig. 1. S936X Integrated Boiler Controller, dimensions in in. (mm).Electrical

Seite 10 - Board” Display

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS3 69-2076—01Table 1. Recommended Ignition Cables.Transformer Requirement:Add current ratin

Seite 11 - LOCATION AND MOUNTING

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS69-2076—01 4WARNINGFire or Explosion Hazard.Can cause severe injury, death or property dam

Seite 12 - OPERATION AND CHECKOUT

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS5 69-2076—01Fig. 3. Align module with slots in control box.Wire the SystemWARNINGElectrica

Seite 13 - Fig. 10. Operating Sequence

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS69-2076—01 6NOTE: Cable length must be 36 in. (0.9 m) or less. The cable must not be in co

Seite 14 - TROUBLESHOOTING

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS7 69-2076—01Fig. 4. Spark Ignition Wiring (S936X).M24216CIRCULATORSPARKIGNITERFLAMESENSEIN

Seite 15 - too many failures during

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS69-2076—01 8Fig. 5. Hot Surface Ignition Wiring (S937X).Common ConnectorsSENSOR 1SENSOR 2G

Seite 16 - APPEARANCE

S9360A, S9361A, S9370A, S9371A INTEGRATED BOILER CONTROLLERS9 69-2076—01a Indicates optional connection based on configuration.HSI Model Specific Conn

Verwandte Modelle: S9370A | S9361A |