Honeywell QUANTUME IS3480 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Barcodeleser Honeywell QUANTUME IS3480 herunter. Honeywell QUANTUME IS3480 User's Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - IS3480 QuantumE

IS3480 QuantumE ® Scan Engine User’s Guide

Seite 2 - Trademarks

6 INSTALLATION RS232, RS232 TTL, Light Pen or Laser Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink

Seite 3 - TABLE OF CONTENTS

7INSTALLATION RS485 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the IS3480. 3.

Seite 4

8 INSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on th

Seite 5 - INTRODUCTION

9INSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socke

Seite 6

10INSTALLATION Low Speed USB (Integrated) 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB PowerLink cable into the 10-p

Seite 7

11INSTALLATION Notes for Laser Emulation IS3480-104 Only The IS3480-104 leaves the factory with the Laser Emulation Mode enabled. If the Reca

Seite 8

12SCANNER OPERATION Configurable Primary and Secondary Scan Pattern Modes There are two configurable scan pattern modes available with the IS348

Seite 9

13SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE ENABLED For illustration purposes the un

Seite 10 - INSTALLATION

14SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON CLICK MODE WITH CODEGATE DISABLED For illustration purposes the u

Seite 11

15SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE ENABLED For illustration purposes the un

Seite 12

Disclaimer Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document

Seite 13

16SCANNER OPERATION Configurable Button Functions SECONDARY SCAN PATTERN BUTTON HOLD MODE WITH CODEGATE DISABLED For illustration purposes the un

Seite 14

17SCANNER OPERATION Sweet Spot Mode The sweet spot mode is used to determine where the maximum read rate area or “sweet spot” is located for a

Seite 15

18SCANNER OPERATION Audible Indicators When the IS3480 is in operation, it can provide audible feedback. These sounds indicate the status of the

Seite 16 - SCANNER OPERATION

19SCANNER OPERATION Visual Indicators There are four LEDs located on the top of the IS3480. When the scanner is on, the flashing or constant il

Seite 17

20SCANNER OPERATION Failure Mode Indicators Flashing Blue and One Razzberry Tone This indicates that the scanner has experienced a laser subsys

Seite 18

21SCANNER OPERATION Depth of Field Specifications* Normal Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 9. Norma

Seite 19

22SCANNER OPERATION Depth of Field Specifications* Reduced Scan Zone Specifications are based on a 0.33 mm (13 mil) bar code. Figure 10. Reduc

Seite 20

23SCANNER OPERATION Depth of Field by Bar Code Element Width* Normal Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19 .

Seite 21

24SCANNER OPERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone MINIMUM BAR CODE ELEMENT WIDTH A B C D E F mm .13 .15 .19

Seite 22

25SCANNER OPERATION IR Activation Range* QuantumE’s default power save mode† is Laser OFF. This power save mode turns the laser off after a con

Seite 23

ii TABLE OF CONTENTS Introduction Product Overview ... 1

Seite 24

26TROUBLESHOOTING GUIDE The following guide is for reference purposes only. Contact a Honeywell representative to preserve the limited warranty t

Seite 25

27TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution All Interfaces The unit scans a bar code, but locks up after the first scan (the whi

Seite 26

28TROUBLESHOOTING GUIDE Symptoms Possible Cause(s) Solution RS232 Only The unit powers up OK and scans OK but does not communicate properly to th

Seite 27

29 DESIGN SPECIFICATIONS IS3480 Operational Normal Depth of Field: 25 mm - 280 mm (1"- 11") 0.33 mm (13 mil) bar code Reduced Dept

Seite 28

30DESIGN SPECIFICATIONS IS3480 Mechanical Width: 63 mm (2.48") Depth: 50 mm (1.97") Height: 68 mm (2.68") Weight: 6 oz (170 g)

Seite 29

31APPLICATIONS AND PROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. SCANNER V

Seite 30 - TROUBLESHOOTING GUIDE

32CONFIGURATION MODES The IS3480 Series scanner has three modes of configuration. • Bar Codes The IS3480 can be configured by scanning the bar co

Seite 31

33UPGRADING THE FIRMWARE The IS3480 is part of Honeywell's line of scanners with flash upgradeable firmware. The upgrade process requires, a

Seite 32

34DEFAULT SETTINGS - COMMUNICATION PARAMETERS Many functions of the scanner can be "configured" - that is enabled or disabled. The scan

Seite 33 - DESIGN SPECIFICATIONS

35DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USBRS232* OR RS232TTL LIGHT PEN RS485KBWLASER EMULATIONExpanded ID “]e0” *  

Seite 34

iii TABLE OF CONTENTS IR Activation Range ... 25 Troubleshoot

Seite 35 - APPLICATIONS AND PROTOCOLS

36DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USBRS232* OR RS232TTL LIGHT PEN RS485KBWLASER EMULATIONTransmit UPC-A Check Digi

Seite 36 - CONFIGURATION MODES

37DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USBRS232* OR RS232TTL LIGHT PEN RS485KBWLASER EMULATION Nixdorf ID   L

Seite 37 - UPGRADING THE FIRMWARE

38DEFAULT SETTINGS - COMMUNICATION PARAMETERS PARAMETER DEFAULT USBRS232* OR RS232TTL LIGHT PENRS485KBWLASER EMULATIONSupplements are not Require

Seite 38 - Host applications

39SCANNER AND CABLE TERMINATIONS Scanner Pinout Connections The IS3480 scanner interfaces terminate to a 10-pin modular socket. The serial numbe

Seite 39

40SCANNER AND CABLE TERMINATIONS Figure 15. IS3480-104 RS232, RS232 TTL, or Laser Emulation Pin Function 1 Ground 2 RS232 Transmit Output 3 RS23

Seite 40

41SCANNER AND CABLE TERMINATIONS Figure 16. Figure 17. Zero Insertion Force Connector (ZIF), 6-pin Utility Connector Pin Function 1 Aux +5V:

Seite 41

42SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53000x-3 coiled or 59-59000x-3 straight

Seite 42

43SCANNER AND CABLE TERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge PowerLink Cable 59-59002x-3 Pin Function 5-Pin DIN,

Seite 43 - Scanner Pinout Connections

44REGULATORY COMPLIANCE Safety ITE Equipment IEC 60950-1: 2005+A11, EN 60950-1:2006+A11 Laser Laser Class 1: IEC 60825-1:2007+A1+A2, EN 60825-1

Seite 44 - Figure 15

45REGULATORY COMPLIANCE EMC Emissions FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity CISPR 24, EN 55024 NOTE: Immunity performance is not

Seite 45 - Figure 17

1INTRODUCTION QuantumE ® is a miniature, omni-directional scanning engine with optional single-line scanning capability. The self-contained devi

Seite 46

46REGULATORY COMPLIANCE EMC Changes or modifications not expressly approved by the party responsible for compliance could void the user’s author

Seite 47

47LIMITED WARRANTY Honeywell International Inc. ("HII") warrants its products and optional accessories to be free from defects in mater

Seite 48 - REGULATORY COMPLIANCE

48LIMITED WARRANTY All provisions of this Limited Warranty are separate and severable, which means that if any provision is held invalid and unenf

Seite 49

49PATENTS For patent information, please refer to www.honeywellaidc.com/patents.

Seite 50

50INDEX A AC ... 2, 6–10 Accessories ... 2, 3 Adapter ...

Seite 51 - LIMITED WARRANTY

51INDEX M Maintenance ... 3 Manual... 2, 18, 31 MetroSelect ...

Seite 52

52CUSTOMER SUPPORT Technical Assistance If you need assistance installing or troubleshooting your device, please call your distributor or the nea

Seite 53 - PATENTS

53CUSTOMER SUPPORT Product Service and Repair Honeywell International Inc. provides service for all its products through service centers througho

Seite 54

54CUSTOMER SUPPORT Online Product Service and Repair Assistance You can also access product service and repair assistance online at www.honeywellaid

Seite 56 - CUSTOMER SUPPORT

2 INTRODUCTION Scanner and Accessories BASIC KIT COMPONENTS Part No. Description IS3480 QuantumE Scanner 00-02026 IS3480 Installation and User’s

Seite 57

Honeywell Scanning & Mobility 9680 Old Bailes Road Fort Mill, SC 29707 www.honeywellaidc.com 00-02026 Rev H 11/10

Seite 58

3INTRODUCTION Scanner and Accessories OPTIONAL ACCESSORIES Part No. Description 59-59002x-3 Keyboard Wedge PowerLink cable 59-59020x-3 Stand

Seite 59

4 INTRODUCTION Scanner Components Figure 1a. Scanner Components ITEM NO. DESCRIPTION 1 Utility Connector Located Under Rubber Seal The rubber

Seite 60

5INTRODUCTION Caution and Serial Number Labels Figure 2. Caution To maintain compliance with applicable standards, all circuits connected t

Kommentare zu diesen Handbüchern

Keine Kommentare