Honeywell
THERMOSTAT
SUBBASES
THE Q539 SUBBASES PROVIDE COOLING ANTICI
PATORS. WIRING TERMINALS. AND MOUNTING
BASES FOR T87F THERMOSTATS. MOST ALSO
PROVIDE SYSTEM AND FAN SWITCHING FOR
HEATING. COOLING. AND HEATING-COOLING
THERMOSTATS.
Screw terminals for electrical connections are letter-
coded for quick, accurate installation.
Shunt type carbon heater provides cooling anticipa
tion for close temperature control.
Guide posts assure mounting and leveling necessary
to maintain thermostat calibration.
Fan and system switch levers (available on most
models) located at top edge for convenient control.
Indicator LED available on most models.
Mount directly on wall or on standard outlet box with
accessory wallplate. i
Q539P with indicator LED for oil primary systems
(HEAT-only).
Q539A,B,C,F,
D.T.
Rev. 10-89
Form Number 60-2246—4
© Honeywell Inc. 1989
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Honeywell

HoneywellTHERMOSTATSUBBASESTHE Q539 SUBBASES PROVIDE COOLING ANTICIPATORS. WIRING TERMINALS. AND MOUNTING BASES FOR T87F THERMOSTATS. MO

Seite 2 - ORDERING INFORMATION

OPERATIONThe Q539 Subbase provides cooling anticipation, wiring terminals, mounting base, and system and fan switching for the T87F Thermostat

Seite 3

NOTES—1160-2246—4

Seite 4 - INSTALLATION

Honeywell Inc.1885 Douglas Drive N.International Sales Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, Fran

Seite 5

SPECIFICATIONSIMPORTANTTHE SPECIFICATIONS GIVEN IN THIS PUBLICATION DO NOT INCLUDE NORMAL MANUFACTURING TOLERANCES. THEREFORE, THIS UNI

Seite 6 - <i) I

TABLE 1—MODEL SPECIFICATIONSMODEL AND DESCRIPTIONSYSTEM SWITCHING (dpst and dp3t)FANSWITCHING(spdt)SUBBASE TERMINALS WIRINGDIAGRAMR W Y BGo X p zRc R»

Seite 7 - 7 60-2246-4

Table 1 (continued)MODEL AND DESCRIPTIONSYSTEM SWITCHING (dpst and dp3t)FANSWITCHING(spdt)SUBBASE TERMINALSWIRINGDIAGRAMR W Y B GO X p zRc R-Q539J1022

Seite 8

they can be pushed back into the wall later.2. In new installations, run wiring (if necessary) to the subbase location.3. Connect the wires to

Seite 9 - CHECKOUT

Q539An'87FHEATING DAMPER MOTOR (IF USED)WITCH_C “<i) IA ^T-0^1COOLING DAMPER MOTOR (IF USED)“1“AA X TERMINAL IS USED ON 0539 MODELS WITH FACTO

Seite 10 - OPERATION

-EXAMPLE;FOR Rc TO Rh JUMPER. STRIP WIRE END LONG ENOUGH TO JOIN BOTH TERMINALS.FIG. 5-JUMPER "R^" AND "R„" TERMINALS FOR CO

Seite 11 - 60-2246—4

PROTECTION AS REQUIRED.És^JUMPER FOR AUTO FAN IN ELECTRIC HEAT APPLICATIONS. IF JUMPER IS USED. MEASURE COMBINED “HEAT RELAY" AND "FAN RELAY

Seite 12 - QUALITY IS KEY

Q539P/T87FAPOWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOADPROTECTION AS REQUIRED.M1029AMOLDED POST (2)VERTICAL PLUMP I LINEOPENING FOR THERMOSTAT