Seitenansicht 0
Honeywell
CT1500, CT1501, CT1502, CT1503
ELECTROMECHANICAL FUEL SAVER
THERMOSTAT AND
WALLPLATE/SUBBASE
CT1500—24 V gas or oil heat.
CT1501 —24 V gas or oi I heat/ cool.
CT1502—24 V central electric heat/cool or single stage heat pump without
auxiliary heat.
CT1503—750 millivolt heat
NOT FOR USE ON LINE VOLTAGE (120 V) SYSTEMS.
INSTALLATION MANUAL
Any questions concerning the appiication of this thermostat should be directed to Honeywell Consumer Services
at 1-800'468-1502, Monday-Friday 7:30 a.m.-5;00 p.m., Central lime.
S.M. Rev 7-91 sHoneywell Inc. 1991 Form Number 69-0273—9
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - WALLPLATE/SUBBASE

HoneywellCT1500, CT1501, CT1502, CT1503 ELECTROMECHANICAL FUEL SAVER THERMOSTAT AND WALLPLATE/SUBBASECT1500—24 V gas or oil heat.CT1501 —24 V gas or o

Seite 2 - THERMOSTAT FEATURES

TABLE 2—TERMINAL DESIGNATIONS.OLD SUBBASE TERMINALCONTROL FUNCTIONR or RHHeating transformer power to control circuit.RCCooling transformer power

Seite 3 - PREPARATION

CT1502, continuedSlUGLE STAGE HEAT PUMP {WiTHOUT AUXILIARY HEAT) SYSTEMIFCOMPRESSOR IS CONNECTED TO OLD THERMOSTAT'S y TERMINAL WITH A JUMPER TO

Seite 4 - UNPACK THERMOSTAT

MOUNT THE THERMOSTAT□ Note the tabs on the top inside edge of the thermostat base. These fit the slots molded into the top of the wallplate or su

Seite 5 - REMOVE OLD THERMOSTAT

SET HEAT ANTICIPATOR LEVERNOTE: Not applicable on CT1503 millivolt model,□ The thermostat’s adjustable heat anticipator must be correctly set to

Seite 6 - MOUNT WALLPLATE OR SUBBASE

□ On the CT1500, CT1501 or CT1502 thermostats, move the heat anticipator indicator to match the number you recorded rn Step 4 or tound on the pr

Seite 7 - 69-0273—9

SET TIMER□ Adjust the timer by moving the knob in clockwise ^ direction. Do NOT reverse the knob.□ When time is correctly set, the Time In

Seite 8 - WIRE WALLPLATE OR SUBBASE

ATTACH THERMOSTAT COVER□ Make sure the packing inserts in the thermostat base have been removed, as explained i n step 3.□ Place the two tabs on uppe

Seite 9 - For CT1501 heating/cooling

CHECK OUT THERMOSTAT OPERATION AND SET TEMPERATURE CONTROL LEVERS□ The two levers on top of the thermostat control the low and high tempe

Seite 10 - CENTRAL ELECTRIC SYSTEM

Heating-only System□ Turn on power to the furnace,Pushbothtemperaturecontrolleverstogetherat least 5“ F [3“ C] above room temperature. The heat should

Seite 11 - SlUGLE STAGE HEAT PUMP

□ After checkout, reset both temperature levers to desired temperatures.For heating season:□ Move the blue lever to the energy savings temper

Seite 12 - MOUNT THE THERMOSTAT

THERMOSTAT FEATURESI—Front of thermostat.HIGHH—Hinged cover lifted.I—Cover removed.24 HOUR PROGRAM DIAL (GREY AREA FOR NIGHT SETTINGS)AAA ALKALI BATTE

Seite 13 - SET HEAT ANTICIPATOR LEVER

HoneywellResidential and Building Controls UivislonHoneywell Inc.1985 Douglas Drive No. Golden Valley, MN 55422Residential and Building Controls Divis

Seite 14 - BATTERIES

PREPARATIONCheck thermostat and wallplate suitability for your heating or heating/cooling system. Refer to Table 1,THERMOSTATMODELSUBBASE OR WALLPLATE

Seite 15 - SET TIMER

□ If wallplate or subbase is mounted on a vertical outlet box (check old installation), order 196393A Cover Plate and Adapter Ring (see appropri

Seite 16 - ATTACH THERMOSTAT COVER

REMOVE OLD THERMOSTAT□ Remove cover of old thermostat. If the cover doesn't snap off when pulled firmly from the bottom, check for a screw that l

Seite 17 - TEMPERATURE CONTROL

MOUNT WALLPLATE OR SUBBASEHEATINQCOOLINGSUBBASE□ If mounting on outlet box, mount as shown on appropriate figure.□ If mounting on wall, hold wallplate

Seite 18 - Heating/Cooling System

3 SCREW h40LES WITH PLASTIC ANCHORSH£ATlNG«:OOUNG SUBBASE□Carefully level the wallplate or subbase and firmly tighten screws.___________SPIR)T LEVELen

Seite 19 - For cooling season;

WIRE WALLPLATE OR SUBBASENOTE: All wiring must comply with local eleotrical codes and ordinances.□ Refer to illustration and strip thermostat wire ins

Seite 20

For CT1501 heating/cooling□ Connect the wires to matching terminals on the subbase.APOWER SOPPLV, PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION A