Setting the cooling program (not
applicable on heating-only model):
Decide when you want the temperature to
reach the comfort level. Find the notch on the
dial that is one-half hour before this time and
insert a
blue
pin. The half-hour head start gives
the air conditioner time to cool the house
before you wake up or arrive home.
Decide when you want the energy savings
period to start and insert a red pin at the notch
that corresponds to this time. After the red pin
engages, the air conditioner will be off until
room temperature rises to the energy savings
setpoint.
Decide when you want the energy savings
period to start and insert a
blue
pin at the
notch that corresponds to this time. After the
blue pin engages, the furnace will be off until
room temperature drops to the energy savings
setpoint.
You can set both a day and a night pro-
gram. See Fig. 5 for program examples.